Aria rolls up her sleeve in the emergency department and asks, “Can I keep my pump on?” She is thirty-eight, has type one diabetes, and needs surgery for an ankle fracture. The pump is giving rapid-acting insulin through a small infusion site. A separate sensor measures glucose in interstitial fluid. The pump uses that signal to adjust delivery. She hasn't had a long-acting insulin injection in years. A resident enters a standard order for correctional insulin and sets her diet to nothing by mouth. Welcome to Pharmacy Snacks. Before verifying the order, ask one question. Where is her next hour of basal insulin coming from?
A healthy pancreas releases insulin between meals. Aria needs that background insulin even when fasting to control glucose production and suppress ketone formation. Her pump delivers small amounts of rapid-acting insulin throughout the day. With no long-acting insulin depot, a disconnected pump, a kinked cannula, or an empty reservoir can create an insulin gap within hours. A glucose of one hundred thirty on arrival tells you what is happening now. It cannot guarantee coverage after transport removes the pump at midnight. The order to hold meal insulin while fasting makes sense. An order to hold every source of insulin creates a different problem entirely.
Start with Aria. She is alert, has been successfully managing her system at home, and can explain her settings, last bolus, and alarm responses. She has supplies for two more infusion set changes. The hospital has a personal pump policy, trained staff, a diabetes team, and a way to record doses. Ask whether she wants to keep managing it and whether her fracture, pain treatment, vision, or dexterity interferes. Check that she can operate the controller, see the screen, inspect the site, and respond to alarms. A preference for continued use and demonstrated ability are important parts of the decision. Reassess them if opioids, delirium, surgery, or the severity of illness changes the picture.
Identify the exact pump, sensor, insulin formulation and concentration, delivery mode, and location of both sites. Record basal settings, carbohydrate ratio, correction factor, glucose target, and insulin action settings as relevant. Download or inspect recent delivery history with the patient and trained team. In automated mode, the programmed basal profile may differ substantially from what the algorithm actually delivered. Check the recent total daily insulin, the basal portion, meal doses, and recent low glucose events. Write units per hour next to each basal rate and units per day next to totals. Confusing those columns can turn a transcription error into a twenty-four-fold dosing error.
Who gives corrections? If Aria is managing an authorized pump, agree on the bolus process with her nurse. Use the required hospital glucose measurements, document when and how much insulin was delivered, and keep duplicate injection orders out of the active regimen. Ask about the last home bolus before giving anything in the hospital. Her pump may have delivered an automated correction on the ride in. An extra bedside injection may be invisible to the algorithm. Both doses will still act in the patient. Make sure staff know what to do if the patient gives an unscheduled bolus, including reviewing insulin on board and checking glucose.
Now the sensor beeps low. Aria says she feels fine and has been lying on the sensor arm. Get a bedside point-of-care glucose promptly. Compression can cause a falsely low sensor reading. Sensor values can also lag behind blood glucose when levels change quickly, and accuracy may suffer with impaired perfusion. Review device-specific medication interferences if readings look implausible. Personal continuous glucose monitoring can offer valuable trends and alarms in appropriate hospitalized patients. Follow institutional requirements for confirmatory bedside glucose, especially for dosing decisions and assessment and treatment of hypoglycemia. If she is severely symptomatic, initiate the hypoglycemia response promptly. Troubleshooting the dashboard comes after addressing the patient.
At noon the operation moves to tomorrow. A short procedure may allow continued pump therapy if the device and sites are compatible with the procedure, the anesthesia team accepts responsibility, staff can access the device, and glucose can be monitored throughout. Discuss whether cautery, positioning, imaging, or the sterile field affects either component. For imaging, check instructions for her exact pump and sensor and the imaging department's safety policy. Know if a removed device can be reconnected or requires a new disposable unit. “Take it off in radiology” needs a named person, a plan for basal insulin, a glucose check, and a plan for what comes next.
Tonight, Aria's pain has increased. She expects to need sedation and several days of inpatient care. She requests injections until she feels ready to manage the device again. Assume she is hemodynamically stable, her pump is working, and she has no ketosis. This is a planned transition. Review her recent insulin delivery and the home profile with endocrinology. In this teaching example, her recent basal delivery is close to the programmed profile, eighteen units per day. Her renal function is stable, with no recent lows. The team selects eighteen units of glargine U one hundred once daily as the initial basal replacement, with reassessment as physiology and intake change. Eighteen is the verified basal component for this patient. Her total daily insulin also includes meal and correction doses.
Time the handoff. The Endocrine Society's planned pump-to-injection conversion gives long-acting basal insulin two hours before discontinuing pump delivery. In our example the nurse gives glargine at eight in the evening and records administration. At ten, the team confirms the dose went in and stops the pump as planned. Document its stop time and who has the device. A dose scheduled at eight but still waiting in the dispensing cabinet has provided zero hours of overlap. Adjust starting doses for current clinical needs under the hospital protocol, especially after repeated lows, reduced renal clearance, or a major change in intake. Never assume another patient's basal rate makes an appropriate default.
Suppose instead the site comes out unexpectedly before dinner. There is no functioning delivery to overlap for two hours. Immediately assess glucose, symptoms, duration of interruption, ketones when indicated, and whether the device can safely be restored. Alert the responsible clinician and promptly establish alternative insulin under protocol. An acutely ill person with ketoacidosis, altered mental status, or critical illness needs a team-managed regimen, often an intravenous infusion. Waiting for long-acting insulin alone to take effect can prolong a dangerous gap. Correct an urgent insulin deficiency and evaluate for a failing infusion site when glucose stays high despite pump corrections. Giving repeated corrections through an unverified site may deliver very little insulin.
Aria is fasting overnight on the injection regimen. Continue appropriate basal insulin. Hold nutritional insulin while she receives no carbohydrate, provide correction insulin as ordered, and monitor glucose on the fasting schedule, commonly every four to six hours on a stable ward. More frequent testing may be needed during a procedure, with intravenous insulin, or after a low. Once she eats, choose an authorized meal insulin regimen matched to intake. Her home carbohydrate ratio can help if she counts carbohydrates reliably and staff can support that approach. Review pain, nausea, kidney function, and new glucocorticoids when interpreting a changing dose requirement.
The next morning, the surgery succeeds. By late afternoon Aria feels ready for her pump. Can she reconnect at her full home basal rate immediately? Yesterday's eight o'clock glargine is still relevant. An unplanned overlap with full pump basal can cause hypoglycemia. Confirm precisely which basal insulin she received, its dose and time, whether another dose is scheduled, and how much activity is likely to remain. Agree with the diabetes team on the restart time and, if appropriate for her device, a temporary basal strategy. Check device-specific limits before using automation. The sensor signal, infusion site, supplies, pump mode, and the patient's capacity all need to be ready. Time the discontinuation of replacement orders and reassess glucose after the change.
Before discharge, ask Aria to show which profile is active and explain what she will do if an infusion site fails again. Verify her backup injection regimen, access to fast-acting insulin and long-acting insulin if prescribed for pump failure, glucose meter, ketone supplies, and hypoglycemia rescue. Put her last hospital basal dose and intended return to the usual settings on the handoff. Give her the diabetes team's contact details and a plan for persistent high readings, vomiting, or ketones. The best pharmacy note in this case could fit on one screen. It names the current insulin source, who operates it, how glucose is confirmed, and the exact time the next source takes over.
Pronunciation guide
- Interstitial — in-ter-STISH-ul
- Glargine — GLAR-jeen
- Basal — BAY-sul
- Bolus — BOH-lus
- Cannula — KAN-yuh-luh
- Ketoacidosis — kee-toh-ass-ih-DOH-sis
Clinical references
- American Diabetes Association — Diabetes Care in the Hospital, Standards of Care 2026
- Endocrine Society — Management of Hyperglycemia in Hospitalized Adult Patients in Non-Critical Care Settings, including pump conversion in Table 3
- International position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps, and automated insulin delivery systems in adults